Arrow

Palais des Festivals

Cultural&leisure

2010

Arrow iconProject overview

Address : Esplanade Georges Pompidou
06400 Cannes
France
Contact person : Frédéric PINGLOT
frederic.pinglot@wicona.com
+33 (0)6.24.25.58.47 - France

Architects : Conception : François Druet - druet.arch.ass@wanadoo.fr - 219 chemin de la Mongiscarde - 31340 - Layrac sur Tarn - France / Architecte Extension : Wilmotte et Associés - contact@wilmotte.fr - 68 faubourg Saint Honoré - 75012 - Paris - France - http://wilmotte.fr/

Fabricator : Difral - contact@difral.fr - 1ere avenue, 6e Rue - 06515 - Carros - France - http://difral.fr/

Other planning committee : Maitre d'ouvrage - SEMEC - contact@palaisdesfestivals.com - 1 boulevard Croisette - 06400 - Cannes - France - http://palaisdesfestivals.com/

Project details : The building, designed by the architects Bennett & Druet, was inaugurated in 1982. The 10,000-m²-big Espace Riviera was added in 1999. The Rotonde Lérins was built in 2006 and offers a fantastic... view over the ocean. Overall, the Palais des Festivals owns an exhibition area of 35,000 m², among it endless halls (among others 18 auditoriums), which are equipped with the newest technology. The facility offers a platform for screenings, performances, conferences and exhibitions

Arrow iconTechnical details

Facade systems

MECANO

Stick type curtain wall with 52 mm sight lines, 2 connecting and sealing solutions: continuous aluminium pressure plates or punctual holders made of polyamide The bearing structure allows for different exterior façade designs: grid, horizontal or vertical cover profiles, SSG, SG BG and punctually held glass for vertical and polygonal façades as well as roof glazing Thermal performance: Ucw 100 % glazed = 1,4 W/m².K with glass Ug = 1,1 W/m².K, Ucw 50 % glazed = 1,1 W/m².K with glass Ug = 1,1 W/m².K Possibility to integrate SSG and SG BG windows as fixed glazing or opening sashes, high thermal performance: Ucw = 1,3 W/m².K with glass Ug global = 1,0 W/m².K, Ucw = 1,1 W/m².K with glass Ug global = 0,7 W/m².K Sound insulation performance RA,tr = 41 dB Trame horizontale Capot de traverse en forme d'ogive ou ronde En vertical, maintien des volumes par un anti-dépresseur ponctuel Joint creux de 22 mm entre les montants Prise de volume de 6 à 42 mm Intégration d'ouvrants VEC Trame verticale Capot en forme darrondie ou droite En horizontal, maintien des volumes par un presseur ponctuel Prise de volume de 6 à 42 mm Intégration d'ouvrants VEC
Built:: - Fixed glazing - Semi façade
Facade systems

MECANO

Stick type curtain wall with 52 mm sight lines, 2 connecting and sealing solutions: continuous aluminium pressure plates or punctual holders made of polyamide The bearing structure allows for different exterior façade designs: grid, horizontal or vertical cover profiles, SSG, SG BG and punctually held glass for vertical and polygonal façades as well as roof glazing Thermal performance: Ucw 100 % glazed = 1,4 W/m².K with glass Ug = 1,1 W/m².K, Ucw 50 % glazed = 1,1 W/m².K with glass Ug = 1,1 W/m².K Possibility to integrate SSG and SG BG windows as fixed glazing or opening sashes, high thermal performance: Ucw = 1,3 W/m².K with glass Ug global = 1,0 W/m².K, Ucw = 1,1 W/m².K with glass Ug global = 0,7 W/m².K Sound insulation performance RA,tr = 41 dB Trame horizontale Capot de traverse en forme d'ogive ou ronde En vertical, maintien des volumes par un anti-dépresseur ponctuel Joint creux de 22 mm entre les montants Prise de volume de 6 à 42 mm Intégration d'ouvrants VEC Trame verticale Capot en forme darrondie ou droite En horizontal, maintien des volumes par un presseur ponctuel Prise de volume de 6 à 42 mm Intégration d'ouvrants VEC
Built:: - Fixed glazing - Conservatories - Semi façade
Door systems

ABSYS Porte

Aluminium hinged and folding doors, thermally broken, with 50 mm frame depth Infill thickness up to 35 mm 3 parts butt hinges with unhinging prevention or surface mounted hinges Burglary resistant with unhinging finger Available in intensive use version, profile wall thickness: 3 mm, large sizes, barrier-free thresholds, endurance test class 8: 1 million opening and closing cycles
Built:: - Double leaf